Morphision test. (a) Plate 1 includes a modified Amsler chart

Morphision test. (a) Plate 1 includes a modified Amsler chart

Price: $ 8.00

4.7(660)

Download scientific diagram | Morphision test. (a) Plate 1 includes a modified Amsler chart consisting of a grid of white lines on a black background with external dimensions of 10 by 10 cm and comprising 16 individual grid squares measuring 2.5 by 2.5 cm. At the center is the fixation point where observers were required to fixate during the presentation of the chart. This plate was used to detect metamorphopsia and localize the area of distortion. (b) Plate 2 includes 4 (A-D) modified Sine Amsler Charts where the straight lines have been replaced by sine curves of different frequencies [half a cycle (A), 1 cycle (B), 2.5 cycles (C), and 4 cycles (D) per 5 cm line], a chart representing a cushion- (E) and a barrel-like (F) distortion. Plates 3-50 consist of 6 groups (series A-F) with 8 charts. (c) shows example of Series C. The plates in individual groups have fixed frequency and increasing amplitudes of distortion in 0.05 degree-steps (from 0.05 to 0.4 degrees) (1-8 plates) from publication: Morphision: A method for subjective evaluation of metamorphopsia in patients with unilateral macular pathology (i.e., full thickness macular hole and epiretinal membrane) | Background: Lack of clinical tests to quantify spatial components of distortion in patients with full thickness macular holes (FTMH) and epiretinal membranes (ERM). Aim: To develop a test for subjective evaluation of visual distortion in the central visual field around | Epiretinal Membrane, Vision Disorders and Patients | ResearchGate, the professional network for scientists.

https://www.researchgate.net/publication/361830195/figure/fig2/AS:11431281097404789@1668567210226/Bar-graphs-showing-comparison-of-contrast-sensitivity-under-mesopic-A-and-photopic-B_Q320.jpg

Morphision test. (a) Plate 1 includes a modified Amsler chart

https://image.slidesharecdn.com/amslergridfinal-130127000156-phpapp02/95/amsler-grid-3-638.jpg?cb=1359245586

Amsler Grid - Types, Procedure of Testing and Clinical Indications

https://www.verywellhealth.com/thmb/FNSgai7mhoVx6nUQHHxSsxCUm10=/400x250/filters:no_upscale():max_bytes(150000):strip_icc()/text-seen-through-eyeglasses-held-my-person-947193174-5b966ac8c9e77c008214811a.jpg

Amsler Grid Visual Field Test: Uses, Procedure, Results

https://www.eyehealthnepal.com/wp-content/uploads/2021/01/amsler-grid-chart-6-and-7.png.webp

Amsler Grid Test Chart For Macular Disease - Eye Health Nepal

https://cdn.slidesharecdn.com/ss_thumbnails/amslargridchart-201120073025-thumbnail.jpg?width=384&fit=bounds

Amsler grid and color vision chart

https://media.springernature.com/lw685/springer-static/image/chp%3A10.1007%2F978-981-15-7644-7_8/MediaObjects/271626_1_En_8_Fig5_HTML.png

Distortion and Scotoma Assessment in Surgical Macular Diseases

https://www.biotoxicity.com/images/muta-ChromoPlate_Ames_Mutagenicity_Flow_Chart.jpg

Muta-ChromoPlate™ Basic Kit

https://www.creative-proteomics.com/upload/image/what-is-ames-test-1.jpg

What is Ames Test? - Creative Proteomics

https://www.garciadeoteyza.es/wp-content/uploads/2017/05/image1.png

METAMORPHOPSIA TEST – AMSLER GRID - García de Oteyza

https://almerja.com/medea/images/image001_574.jpg

Most probable number (MPN) method APHA 2001 for total coliforms, thermotolerant coliforms and E. coli in foods

https://maculacenter.com/wp/wp-content/uploads/2012/12/title-video-macular-pucker-12-17-12.jpg

Amsler grid eye test for detecting macular problems